Safety and Buildings Safety and
Buildings Division
POWTS MANAGEMENT RESPONSIBILITIES MATRIX
Comm 83, Wis. Adm. Code
| July
1, 2000 to Present |
Before July 1, 2000
| |
Applies
to all systems installed or modified on/after 7/1/00.
|
Applies to all systems existing
prior to 7/1/00. | |
Comm 83.52 (1) (a). The owner is responsible for ensuring
that maintenance is completed. |
Comm 83.52 (1) (b). The owner is responsible for ensuring
that maintenance is completed. |
| Comm 83.52
(1) (a) requires the
owner to follow a management plan approved under Comm 83.54 (1), Wis.
Adm. Code. |
Comm 83.52 (1) (b) requires the owner to ensure that the system is
maintained pursuant to Comm 83.54 (4) (a) to (d) Wis. Adm. Code.
| |
Comm
83.52 (1) (c) 1. The owner must have a maintenance or service
contract with a registered POWTS Maintainer if the management plan
requires maintenance, monitoring or evaluation at an interval of 12
months or less. |
Comm 83.54 (4) (a). Septic tanks must be serviced when the volume of
sludge and scum occupies 1/3 the volume of the tank.
Service by certified septage servicing operator (pumper). |
|
Comm 83.52 (1)
(c) 2. The owner must have a maintenance or service contract with a
certified septage servicing operator (pumper) if the management plan
involves servicing (i.e. pumping) any component at an interval of 12
months or less. |
Comm 83.54 (4) (b). Holding tanks must be serviced when the liquid
level is one foot below the inlet invert of the tank (i.e. when the
alarm is activated). Service by certified
septage servicing operator (pumper). |
| Comm
83.21 (2)(c) 5. Requires that
prior to state sanitary permit issuance evidence of the requirement for
maintenance, service, evaluation, or monitoring of a POWTS be recorded
on the deed if the management plan specifies such activities occur at
an interval of 12 months or less. |
Comm 83.54 (4) (c). Service as per manufacturer's or
designer's instructions for components other than septic or holding
tanks. Service by registered POWTS Maintainer.
| |
Service,
maintenance, and inspection is provided by appropriately
licensed, certified or registered persons. |
Comm 83.54 (4) (d). Visual inspection once every 3 years for
evidence of surface ponding. Inspection by
licensed Master Plumber, Master Plumber-Restricted Service, Certified
POWTS Inspector, or Licensed Septage Servicing Operator (Pumper).
|
Email
this page's manager, Todd Taylor, Todd.Taylor@Wisconsin.gov
The Department of Safety and Professional Services Safety and Buildings
Division is an equal opportunity service provider and employer. If you
need assistance to access services or need material in an alternate
format, please contact us, 608-266-3151, TTY 608-264-8777, or Todd.Taylor@Wisconsin.gov
|