Lastname, Firstname 2004-06-22 2004-06-22 2005-06-30 Wisconsin Department of Safety and Professional Services, Division of Safety and Buildings Wisconsin Department of Safety and Professional Services, Division of Safety and Buildings, Commerce, Safety and Buildings, Comm, Credentials, Certifications, Buildings Codes, Registrations, Construction, Public Safety, Licenses, Permits, License application forms, Trades, Administrative codes, Regulations, Statutes, Administrative rules, Cities, City, Towns, County, Counties, Municipal, Ordinances, Hygiene, Hazardous, Diseases, Design, Engineering, Continuing education, Audits, Grants, POWTS, Private wastewater treatment systems, Septic field, Septic tanks, Sewage treatment, Sewage disposal, Accessibility, Accessible, Disability, Disabilities, Clean air, Clean water, Air quality, Public sector employees, Applications, Plan review, State, Bureau of Program Development, Bureau of Field Operations, Bureau of Integrated Services, Environmental assessments, Environmental impact statement, Soil erosion, Drinking water, Appliances, Plumbing Products, Fire prevention and protection, Firefighter safety, Fire Sprinklers, Rental unit energy efficiency, Rental weatherization, Commercial buildings, Forms, Publications, Plumbing, Inspection, Inspectors, Consultants, Waste disposal, Historic buildings, Occupational and industrial safety, Occupational health, One and two family dwellings, Houses, Housing, Homes, Multifamily dwellings, Mine Safety, Mining, Mines, Open pits, Quarries, Blasters, Plumbers, Electricians, Boilers, Wastewater, Elevators, Lighting, Energy, Mobile homes, Manufactured homes, Welding, Structural systems, Gas systems, HVAC, Refrigeration, Public swimming pools, Wisconsin Fund, Explosives, Amusement rides and attractions, Tramways lifts and tows, Government facts figures and statistics Wisconsin Department of Safety and Professional Services, Division of Safety and Buildings, Commerce, Safety and Buildings, Building, Wisconsin, Safety, Construction, License. Safety and Buildings Division - Articles from the February, 2000 Wisconsin Plumbing Codes Report Articles from the February, 2000 Wisconsin Plumbing Codes Report (or choose PDF copy.) You can choose from the list of articles or scroll down: 1. Comm 83 poised to go into effect; 2. Revisions more clearly define combination plumbing/sprinkler systems, also make license code changes; 3. Event Calendar; 4. Sometimes, counting fixtures is key to plumbing plan review; 5. Pedestal shampoo bowls and circular wash fountains can be installed with greater vertical distances from the trap line; 6. RP valves don't magically change potable water to nonpotable; 7. Some POWTS systems may be under scrutiny as injection wells; 8. More information available from new division home page; 9. What can you find on the S&B Home Page?; 10. You don't use a computer?; 11. Well Pump Electrical Question; 12. License Violations; 13. Employment Opportunities   Comm 83 poised to go into effect Revisions to Comm 83, the Private Onsite Wastewater Treatment Systems (POWTS) code, could go into effect in June or July, 2000. That is the estimate of Safety and Buildings Division staff after the final draft code passed review by two state legislative committees, and was formally adopted by the Secretary of the Department of Safety and Professional Services, Brenda Blanchard. Sent to the committees after several years of hearings and discussions, the final draft reflected input about earlier drafts from the public, code administrators, and legislators. The code will be sent to the state Revisor of Statutes for legal printing and publishing. After printing, the code has a two-month delay before going into effect. There have been threats of lawsuits to stop implementation of the code. As the first major changes of Comm 83 in almost two decades, the revisions address current health and safety issues and priorities, and reflect changing technologies, methods, and materials. The new code would notably cover use of modern POWTS technologies that previously had not been available to owners of new construction. For the purposes of local training, planning, and administration, until January 1, 2003 counties may control by ordinance use of some of these technologies for new construction. All the technologies will be available for use as replacement systems. Localities will continue oversight of holding tanks. The code does not specifically dictate as many installation mandates as in the past. Instead, the revised code allows owners and designers varying methods for treating wastewater in relation to individual site circumstances. Maintenance of systems is a major aspect of assuring health and safety. People will be able to obtain a new credential to provide required monitoring and maintenance services for POWTS. S&B is preparing training in the new code provisions. As it is available, more information will be printed in the WPCR and be posted on the S&B WebStite. That training will provide continuing education credits for many plumbing categories. The final draft code now is posted on the S&B WebSite, http://www.commerce.state.wi.us/SB/SB-HomePage.html (PDF, 308 KB). The date of availability of printed copies of the new code is uncertain. The printed copies will be announced in the WPCR and on the WebSite. Technical questions on the code can be directed to Roman Kaminski, S&B POWTS Program Manager, 715 345-5334, rkaminski@commerce.state.wi.us, or Jim Quast, Credentialing Program Manager, 608-266-9292, jquast@commerce.state.wi.us. Choose this image to go back to the top.   Revisions more clearly define combination plumbing/sprinkler systems, also make license code changes A very important code change package involving combination fire sprinkler/plumbing systems in one- and two-family dwellings has been adopted by Department of Safety and Professional Services Secretary, Brenda Blanchard. The code revisions more clearly define combination systems as plumbing, meaning licensed plumbers must do the installation and maintenance work. Standards are specified for the systems when they are voluntarily installed by homeowners. Fire sprinkler systems are not mandated in one- and two-family dwellings. The revisions to Comm 82, the Plumbing Code, and Comm 84, the Plumbing Products Code, passed review by legislative oversight committees. The effective date could be this spring, in May or June, after the legal process of printing and publishing. The revision package also makes changes to Comm 5, the Credentialing Code, replacing the word "credential" with "license, certification, or registration," or with the specific word "license," "certification," or "registration," as applicable. There are also Comm 5 changes relating to fire sprinkler licenses. Under the current rules, any individual may apply for and take the license examination for an automatic fire sprinkler contractor. However, someone who wishes to take the license exam for a journeyman automatic fire sprinkler fitter must first have completed a sprinkler system apprenticeship. The new rules contain specific training and experience qualifications for individuals applying for the automatic fire sprinkler contractor license. The new rules also specify the hours of continuing education required for renewal of automatic fire sprinkler contractor licenses, journeyman automatic fire sprinkler fitter licenses, and automatic fire sprinkler contractor-maintenance registrations. In accordance with new state laws, the new rules set requirements when an applicant or licensee does not provide required information, is delinquent in required payments, or fails to comply with a subpoena or warrant. The person must provide their social security number or federal employer identification number. The person must not be delinquent in tax payments or child support payments. And the person must not have failed to comply with a subpoena or warrant issued by the state Department of Workforce Development or a county child support agency relating to paternity or child support proceedings. Choose this image to go back to the top.   Event Calendar Contact the listed Code Consultant for information on the meetings agenda, locations, etc. If you have questions concerning technicalities of codes which are subjects of the meetings, contact consultants and reviewers listed on page 2 of this WPCR. March 7, 2000 - Tuesday - Commercial Building Code Council and Multifamily Dwelling Code Council - 9:15 a.m. to 3 p.m. - Department of Agriculture, Trade, and Consumer Protection - 2811 Agriculture Dr, Rm. 106 - Sam Rockweiler, 608-266-0797, srockweiler@commerce.state.wi.us March 16, 2000 -Thursday- Plumbing Advisory Code Council - 9 a.m. to 3 p.m. - Thompson Bldg., Rm. 3B, 201 W Washington Ave., Madison - Jean MacCubbin, 608-266-0955, jmaccubbin@ commerce.state.wi.us March 23, 2000 - Thursday - Pool Code Advisory Council - 9a.m. - 3 p.m. - Sun Prairie Public Library - 1350 Linnerud Dr. - Jean MacCubbin, 608-266-0955, jmaccubbin@commerce.state.wi.us March 28, 2000 - Tuesday - HVAC Code Council - 8:30 a.m -2 p.m. -WHEDA Building, Rm. 3B, 201 W Washington Ave., Madison - Jean MacCubbin, 608-266-0955, jmaccubbin@commerce.state.wi.us Choose this image to go back to the top.   Sometimes, counting fixtures is key to plumbing plan review Deciding whether a plumbing plan review is needed can depend on knowing what to count as a plumbing fixture, because there is a minimum threshold number of fixtures. Plumbing installations involving 11 or more plumbing fixtures currently must be submitted to the Safety and Buildings Division or an agent municipality for review and approval.* Table 82.30-1 lists a few specific fixtures. Examples of plumbing fixtures not mentioned in Table 82.30-1, but which are included in counting fixtures to decide if a review is needed: sinks, tubs, floor drains, hose bibbs, sill cocks, wall hydrants, roof drains, exterior and interior storm water inlets, water heaters, or garage catch basins. Most any device connected to the sanitary, potable water distribution, or storm water drainage systems in a public building is a fixture. On the other hand, installation of some types of plumbing fixtures or systems must be submitted for review regardless of the number of plumbing fixtures involved. Those fixtures or systems, such as grease interceptors for public buildings, or private interceptor main sewers, are specifically listed in table 82.20-2. For more information, contact any of the plumbing plan reviewers or consultants listed on page 2 of the printed WPCR or use the Contacts link above left. *Note that a fee change proposal being considered by S&B includes raising the review threshold to 16 fixtures. See last month's WPCR. Choose this image to go back to the top.   Pedestal shampoo bowls and circular wash fountains can be installed with greater vertical distances from the trap line Circular wash fountains and pedestal shampoo bowls may be installed with a maximum vertical distance of 36 inches to the center of the trap outlet. Because of the construction of these fixtures, the 36 inch vertical distance exception is necessary to allow their installation as a pedestal fixture. Comm 82.32(4)(b)1 contains requirements for the vertical distance from fixture or drain inlets to the horizontal center line of the trap outlet. This code section states that the maximum vertical distance from the fixture drain outlet to the center of the trap outlet is 15 inches, with a few exceptions. One of the exceptions is for floor drains and standpipe receptors: "The vertical distance between the top of the strainer of a floor drain or the opening of a standpipe receptor and the horizontal center line of the trap outlet shall not exceed 36 inches" If you have questions regarding the installation of the pedestal shampoo bowl or the circular wash fountain, contact Curt Wendorff at 715-526-9056 or cwendorff@commerce.state.wi.us. Choose this image to go back to the top.   RP valves don't magically change potable water to nonpotable by Jim Wehinger, S&B Plumbing Consultant, jwehinger@commerce.state.wi.us, 608-339-7430 Recent inquiries to the Safety and Buildings Division asked when and how to label piping downstream of a backflow preventer such as a reduced pressure principle backflow preventer (RP). If you are confused, you are not alone. There is a misconception about this issue. The misconception is; "Anytime a RP is installed in a piping system, the downstream piping must be labeled as "Nonpotable." That's not correct. The RP in itself does not miraculously change the downstream water from potable to nonpotable. The purpose of a RP is to stop the unwanted reverse flow in a piping system. The materials used in the construction of the piping system, and what the water is actually being used for, determine whether the water is potable or nonpotable. For example, a piping system installed to provide potable water to plumbing fixtures or appliances, and having individual protection at each point of use, would comply with the code as a potable water piping system. The installation of a RP in this system in advance of the connection of any fixture or appliance would change nothing; the use remains potable. An RP can be installed as a containment assembly, in addition to the required isolation backflow protection at each point of use. It is sort of an insurance policy or back-up to the isolation. The RP for this type of installation should be labeled "FOR CONTAINMENT PURPOSES ONLY" to indicate its use on a potable system, and hopefully to help prevent mistaken nonpotable connections downstream. Comm 82.41(3) requires "Isolation," or individual protection of the potable water supply at each point of use for each fixture, each piece of equipment, or each appliance requiring potable water. As the designer or installer, you may chose to use containment in addition to isolation for a particular piping system. However, the choice of labeling would not change to nonpotable because of the containment installation of an RP. Remember, the code requires that plumbing fixtures and appliances be provided with only potable water. Note: Comm 82.41(3)(c) requires containment in addition to isolation only for waste water treatment plants and marinas. A single RP installed to serve multiple outlets not requiring potable water would be a nonpotable piping system. A nonpotable piping system could supply water to things such as seal lubricating water on raw sewage pumps, or boilers for heat. Looking at other code requirements, in part: Comm 82.40(3)(a) Potable water required. Every piece of equipment used in the preparation or processing of food, medical or pharmaceutical products ,and every plumbing fixture and appliance which demands a supply of water, shall be provided with only potable water. Comm 82.40(3)(d), Identification. 1. Where a building or a structure is served by a nonpotable water distribution system and a potable water distribution system, each distribution shall be identified in accordance with this subdivision. a. All above ground piping supplying nonpotable water shall be identified nonpotable by tags or yellow bands. The yellow bands shall be at least 3 inches wide. b. All above ground piping supplying potable water shall be identified by tags or green bands. The green bands shall be at least 3 inches wide. To summarize: 1. Every plumbing fixture and appliance shall be provided with only potable water, 2. If a building or structure has multiple piping systems, one which carries nonpotable water, and one which carries potable water, each piping system shall be identified (labeled) as either nonpotable or potable.
  1. Each plumbing fixture, each piece of equipment, and each appliance shall be provided with a means of individual backflow protection (isolation).
  2. A means of backflow protection shall be provided for each nonpotable piping system (containment).
Choose this image to go back to the top.   Some POWTS systems may be under scrutiny as injection wells by Roman Kaminski, S&B POWTS Program Manager, rkaminski@commerce.state.wi.us, 715-345-5334 Class V injection wells are typically shallow disposal systems that are used to place a variety of fluids below ground surface. Injection wells are regulated by the federal Environmental Protection Agency and the states, through what is known as the Underground Injection Control (UIC) program. Recently, the EPA issued new regulatory requirements intended to protect public health and the environment by eliminating or reducing injection of wastes from large capacity cesspools and motor vehicle waste disposal wells. Large-capacity Cesspools - New cesspools are prohibited nationwide as of April 2000. - Existing cesspools will be phased out nationwide by April 2005. Motor Vehicle Waste Disposal Wells - New wells are prohibited nationwide as of April 2000. - Existing wells in regulated areas will be phased out, but owners and operators will be able to seek a waiver and obtain a permit. Staff of the Wisconsin Department of Natural Resources indicate they are not aware of any "large-capacity cesspool" installations. However, there are quite a few service stations, garages, and other facilities that are served by onsite sewage systems that may meet the definition of a "Motor Vehicle Waste Disposal Well." DNR staff further indicate that in the near future they will develop and present guidance regarding this issue. Anyone who is considering installing a new or replacement onsite sewage system that could be classified as a Motor Vehicle Waste Disposal Well should contact the DNR early in their planning process about what type of onsite sewage system would be acceptable for their facility. For example, depending on the type of wastewater being generated in a service station, garage, or even a town hall that has a storage facility for town mechanical equipment, it may be necessary to segregate the waste stream. The "domestic wastewater" could be routed to a traditional soil-based sewage disposal system while the "non-domestic wastewater" (from the garage area) may have to be routed to a holding tank system. The federal regulations that cover Class V Injection Wells are available on the EPA's website at www.epa.gov/safewater/uic.html#classv. I will provide updates in future WPCR issues. Choose this image to go back to the top.   More information available from new division home page More information is now available on the Internet from the Safety and Buildings Division's new Home Page, http://www.commerce.state.wi.us/SB/SB-HomePage.html. The new Home Page is based on S&B experience with what our WebSite users are requesting. Also, more initial choices are offered in an effort to shorten the path to specific points. It is important that users provide feedback on S&B WebSite improvements they think of or about any problems encountered. Each page on the WebSite has an email link to a person responsible for the page. Not every problem can be solved, and S&B resources are limited; however the division gets its best suggestions from customers. The division has retained the S&B first page that has been offering five paths into various S&B information, retaining an address WebSite users have set as a favorite or bookmark. That first page's address is http://www.commerce.state.wi.us/COM/Com-Safety-and-Buildings.html. Choose this image to go back to the top. What can you find on the S&B   Home Page? About S&B is a general outline of what the Safety and Buildings Division does, with email contact links to the division's managers. Contacts provides several ways to contact individual S&B staff, a listing of who can answer questions about various topics, listings of staff responsibilities - by county, by inspector, and by program district maps. Programs links to pages for about 30 individual S&B programs. Forms offers some of the division forms for printing off or downloading, in Portable Data Format (PDF), and as Word 97 files. These forms are not set up to be filled in and submitted via the WebSite. Events lists meetings of advisory code committees and councils, and of code hearings. Code Changes contains the most recent code hearing announcements and code proposal drafts. Plan Review Appointments offers a calendar of when plan review appointments are available in each S&B plan review office, with an ability to email or fax appointment information. Publications includes the latest issues of the Wisconsin Building Codes Report, the Wisconsin Plumbing Codes Report, Mine Safety Newsletter, and Rental Energy Efficiency Newsletter, plus access to archives of some previous issues. Codes provides links to copies of codes S&B administers, and to sources of state government code-related information. Office Locations provides address, contact information, and some maps for S&B offices. Help for Site Users gives tips on using the S&B WebSite. Explanation of File Formats provides info on different kinds of files used on the S&B WebSite and several links to free software that assist use of S&B files. Feedback offers an opportunity to send email to the division concerning the WebSite. Choose this image to go back to the top.   You don't use a computer? While S&B is trying to satisfy many requests for more information on the Internet, if you couldn't care less about computers, the division doesn't discount your needs. If you need information from S&B, contact the people listed on page 2 of the WPCR, use the contacts link on the left at the top of this document, or call 608-266-3151. Choose this image to go back to the top.   Well Pump Electrical Question A submersible well pump with two-wire well cable is replaced. Does the new pump require an equipment-grounding conductor? If so, where should the equipment ground be connected if the branch circuit cable does not have an equipment-grounding conductor? Yes to the first question. See NEC 250-112(l). The second answer: the new cable should have an equipment-grounding conductor connected to the pump. If the branch circuit cable has an equipment-grounding conductor, connect the two together inside the well cap. Use a bonding jumper to connect the well casing to the two equipment grounds. If the branch circuit cable does not have an equipment ground, do not connect the pump-grounding conductor to the casing. Tape it off inside the well head for future connection when branch circuit conductors are replaced. Choose this image to go back to the top. March 2000 is the time to be aware of the status of   pumbing licenses Safety and Buildings Division staff have noticed a considerably higher number of plumbing license requests for petitions for late renewal, late continuing education, and or reexamination, compared to requests from other license categories. Some of these requests came from people who worked more than a year without realizing their license expired. To heighten awareness of having current credentials, S&B is asking the plumbing industry in general to pay extreme attention during the month of March to assuring all submitted plans, requests for permits, and installations are done by properly-licensed people. Check your card first. Many plumbing licenses expire March 31. Are all your licenses current? Are some nearing expiration? Do you still need more continuing ed credits. Have you seen a renewal application. Ask people you work with. Do they all have the proper license to do the work assigned, work for which a Master is ultimately legally responsible? It is not only the law, but also good business practice to only hire properly-licensed staff, for more assurance of work done correctly. Employers and employees need to think about liabilities and legal action for license violation, poor work, or lien problems. Plan reviewers and inspectors will make special efforts in March to check the status of credentials on projects they encounter. Check people around you. To meet daily customer requests for credential status information (and cut down on the number of phone calls S&B receives) has lists of people with current plumbing credentials on the S&B WebSite, either from The Plumbing Program Page, http://www.commerce.state.wi.us/SB/SB-Plumbing Program.html, The POWTS Program Page, http://www.commerce.state.wi.us/SB/SB-POWTS Program.html, The Credential Program Page, http://www.commerce.state.wi.us/SB/SB-Credential Program.html, Or, directly, http://www.commerce.state. wi.us/SB/SB-PlumbingPowtsCredentialList.html. The lists will be updated after monthly exams are graded and new credentials issued. Since S&B issues new licenses each work day, WebSite lists may not be complete at all times. For more information, contact the S&B Licensing Unit, 608-261-8500, madisoncred@commerce. state.wi.us. Choose this image to go back to the top.   License Violation Reports, April 1, 1999 - November 30, 1999 Unlawful Hiring
Date Last Name First Name City Municipality
9/29/99 JENTIN SCOTT HINGHAM SHEBOYGAN
4/8/99 LASTER ALVIN MILWAUKEE MILWAUKEE
9/10/99 MC HUGH DAN M ONALASKA MAUSTON
4/29/99 MURDOCK KEITH TOMAH WARRENS
11/2/99 PECHA TODD BLOOMER EAU CLAIRE
11/2/99 PECHA TERRY BLOOMER EAU CLAIRE
8/11/99 REDINGER EDWARD MARENGO ASHLAND
Wrong License
Date Last Name First Name City Municipality
9/30/99 DUITMAN PLBG FOND DU LAC FOND DU LAC
9/30/99 LAKE WAYNE GRANTSBURG GRANTSBURG
8/19/99 MADSEN WILLIAM R RACINE OAK CREEK
5/6/99 MULLNER BILL LOCKPORT ARBOR VITAE
4/27/99 RING BRIAN P DE FOREST WESTPORT
7/30/99 ROBINSON RICHARD T LA CROSSE LA CROSSE
Other or multiple
Date Last Name First Name City Municipality
6/28/99 No License Advertising MCNAMARA JR MARLYN CADOTT
9/17/99 No License, Wrong License,SCHMIDT, JAMES J, APPLETON, APPLE.
10/20/99 No License, Wrong License,SCHROEDER, MARKP, EDWARDS, EAU Claire Claire
6/15/99 No License, Wrong License, MELL, BRANDEN, DULUTH SUPERIOR
No License
Date Last Name First Name City Municipality
10/26/99 ANDRE JOHN V EAU CLAIRE EAU CLAIRE
5/5/99 BAILEY JIM C WOODRUFF
8/25/99 BALDE FRED PLYMOUTH ADELL
4/29/99 BAUER DENNIS WARRENS WARRENS
4/29/99 BAUER TOM TOMAH WARRENS
10/20/99 BOGART JAMES F AUGUSTA EAU CLAIRE
11/9/99 9 BRUHN DAVID TWO RIVERS TWO RIVERS
8/23/99 CARTER IVY MILWAUKEE MILWAUKEE
4/27/99 CORNWALL DAREN WESTPORT
9/10/99 DEAN DENNIS J S. MILWAUKEE OAK CREEK
11/2/99 DELFIELD STEVE FOND DU LAC FOND DU LAC
9/1/99 DOWNEY JIM SPOONER LADYSMITH
4/6/99 GABBERT JAY A PLOVER STEVENS POINT
9/9/99 GERKE RICHARD TOMA VIROQUA
10/6/99 HANSEN ERIC KENOSHA KENOSHA
5/3/99 HEINDL DAVID E KAUKANA GREENVILLE
7/15/99 HEINIG SCOTT G PLYMOUTH RHINE
8/11/99 JACOBSON EXCAVA V. HEIGHTS RIVER FALLS
10/18/99 JERECZEK ARVID N EAU CLAIRE EAU CLAIRE
8/11/99 JOHNSON CRAIG IRON RIVER ASHLAND
4/27/99 JOHNSON CURTIS E SUN PRAIRIE WESTPORT
7/21/99 JOHNSON JAY MADISON FITCHBURG
6/5/99 KEANE JAMES M THREE LAKES RHINELANDER
4/8/99 KING JR LOVELL MILWUAKEE MILWAUKEE
4/8/99 KOSIDOWSKI JAMES C MERCER MERCER
9/29/99 LAWRENCE RICHARD SHEBOYGAN SHEBOYGAN
9/21/99 MAASS FRANCIS G FORT ATKINSON MEQUON
4/12/99 MAHN TROY MENASHA SHEBOYGAN
6/1/99 MANSKE LESTER STODDARD LA CROSSE
5/10/99 MUCHE BILL MAYVILLE OHAWA
10/8/99 PELOCK DENNIS GAYS MILLS MOUNT STERLING
9/24/99 PENMAN GARY G HAYWARD LENROOT
9/27/99 PERSCHKE KLAUS A N FOND DU LAC FOND DU LAC
10/25/99 SCHOTT J BRIAN VIROQUA EAU CLAIRE
9/27/99 SCHULTZE JOHN LITTLE CHUTE MANITOWOC
5/3/99 SHEFCHIK TONY GREEN BAY? GREEN BAY?
5/12/99 SMITH LLOYD MAUSTON FOUNTAIN
5/3/99 SPOEHR DONALD T NEW LONDON GREENVILLE
9/29/99 TEBBIN VERN STILLWATER LENROOT
9/16/99 TRIER WEILER CONST MARSHFIELD MARSHFIELD
9/10/99 TYLKA ANDREW HOLMEN MAUSTON
10/8/99 WALDNER DAN RICHLAND CENTER
10/19/99 WELD RICHARD G EAU CLAIRE EAU CLAIRE
10/20/99 WELD RICHARD G EAU CLAIRE EAU CLAIRE
4/27/99 WEST SHANE T MADISON WESTPORT
9/10/99 WIATT RAY LA CROSSE MAUSTON
4/26/99 WIZA BRUCE A STEVENS POINT CARSON
5/4/99 ZITZELSBERGER DAVID D MENASHA FREEDOM
No license: Does not possess a valid license, certification, or registration required under chapter 145, Wisconsin Statutes, while involved in the activity. Wrong license: Possesses a valid license, certification, or registration issued under chapter 145, Wisconsin Statutes, but involvement in the activity is beyond the scope of the credential. Unlawful hiring practice: An individual possessing a license, certification, or registration issued under chapter 145, Wisconsin Statutes, employes, allows, or directs another individual who does not possess a valid and/or appropriate credential required for the activity. Advertising: The advertisement offering to provide plumbing services does not conform with the specification of section 145.11, Wisconsin Statutes. Choose this image to go back to the top.   Employment Opportunity (See more opportunities, http://www.commerce.state.wi.us/SB/SB-HomePage.html) Private Sewage Plan Reviewer 2- Stevens Point Department of Safety and Professional Services; Division of Safety and Buildings Division, Field Operations Bureau, Stevens Point. Salary: $35,579 per year plus excellent benefits. This classification is included in the Technical Bargaining unit of the Wisconsin State Employees Union (WSEU). Duties: Conduct soil and site investigations for proposed unsewered plats and individual private sewage sites; inspect private sewage systems under construction and existing systems to determine compliance with health and safety codes. Examine plans for private sewage systems to determine compliance with Chapt. 145, Wis. Stats and Chapts. Comm 82-84, Wis. Adm. Codes. Make final determinations for petitions for variance; provide consultative services to engineers and other professionals concerning code enforcement and design issues; develop and present technical training sessions; enforce related statutes and administrative rules. Well-qualified candidates will be licensed as a Master or Journey Plumber or Soil Scientist, registered as a Designer of Engineering Systems, Professional Engineer (PE, EIT) and/or have post-secondary education in a relevant field. All candidates must be certified as a Private On-site Wastewater Treatment Systems (POWTS) Inspector AND Certified Soil Tester or have the ability to obtain certification within 6 months of hire. Knowledge and skills: Wisconsin Uniform Plumbing Code (Comm 82-87) with emphasis on the private on-site wastewater treatment systems Code (Comm 83;) Wisconsin Administrative Code COMM 3 and 5; and State Statutes (101, 145,236, and 254) governing plumbing credentialing and plumbing design and installation techniques; Soil / site analysis principles and techniques; engineering principles involved in plumbing; skill in preparing, reading and interpreting blueprints, designs, plans and specifications for plumbing systems; groundwater monitoring systems and hydrologic and pneumatic principles and practices as they relate to plumbing systems; computations and calculations involved in plumbing; flow theories used in engineering for the plan review function; and effective oral, written and interpersonal communication techniques. Candidates must have a valid Wisconsin Driver's license or be able to obtain one. The ability to maneuver around varied terrain, climb, stoop, and bend and work out of doors for periods of time to conduct field inspections is required. How to Apply: For additional information, contact: Dale Bartz; Commerce Human Resources; 201 W. Washington Ave; PO Box 7970; Madison, WI 53707-7970; e-mail: dbartz@commerce.state.wi.us ; phone: 608-266-0366; FAX 608-266-0182. Choose this image to go back to the top. Fifteenth annual   POWTS Management Teleconference - ETN The POWTS Management teleconference is scheduled for Wednesday, March 22, 8:30 am - 10:20 am. The audio teleconference provides a convenient and timely interaction about POWTS research, codes, and educational opportunities. The session provides 1.5 credit hours for MP, MPRS, JP, JPRS, PI, and CST credentials. The Educational Teleconference Network (ETN) is a statewide party line of two-way speaker telephones. An ETN participation site is available in each county. For registration or additional information, contact Joyce McConnell or Jim Peterson at UW-Madison Env. Resources Center, 608 262-0020; Fax 262 2031; email jopeters@facstaff.wisc.edu. Check website: http://www.wisc.edu/sswmp/ for additional educational opportunities. Email page manager, Todd Taylor, Todd.Taylor@Wisconsin.gov The Department of Safety and Professional Services Safety and Buildings Division is an equal opportunity service provider and employer. If you need assistance to access services or need material in an alternate format, please contact us, 608-266-3151, TTY 608-264-8777, or Todd.Taylor@Wisconsin.gov.